收藏我们   ENGLISH  
论文查询
范围:  
提 交
《化学分析计量》 2021年第11期
DOI:10.3969/j.issn.1008-6145.2021.11.003
连续流动分析法快速测定加热不燃烧卷烟专用新型薄片中甲醛、乙醛的醛基总含量
王春琼1,陈丹1,秦世春1,彭丽娟1,缪祥坤2,孙杨雨2,李苓1,张燕1,曾天宝3
1.云南省烟草质量监督检测站,昆明 650106 2.红云红河烟草集团,昆明 650231 3.深圳市一正科技有限公司,广东深圳 518101 
Rapid determination of total aldehyde group contents of formaldehyde and acetaldehyde in new HNB cigarette sheet by continuous flow analysis
王春琼1,陈丹1,秦世春1,彭丽娟1,缪祥坤2,孙杨雨2,李苓1,张燕1,曾天宝3
1. Yunnan Tobacco Quality Supervision and Test Station, Kunming 650106, China; 2. Hongyun Honghe Tobacco Group, Kunming 650231, China; 3. Shenzhen E–Zheng Tech Co., Ltd., Shenzhen 518000, China 
摘要:建立连续流动分析法快速测定加热不燃烧(HNB)卷烟专用新型薄片中甲醛和乙醛的醛基总含量。称取剪碎的HNB专用新型薄片样品(0.5 cm×0.5 cm)0.500 0 g,加入0.01 mol/L的氢氧化钠溶液50 mL和1.5 g活性炭,振荡1 h,过滤,收集滤液。滤液中醛基与酚试剂在线反应生嗪,嗪在酸性溶液中被高价铁离子氧化形成在630 nm波长处有吸收的蓝绿色复合物,采用连续流动-分光光度法监测630 nm处吸光度的变化,可推算得到薄片中甲醛和乙醛的醛基总含量。该方法仪器流路流量最佳配置为样品溶液和硫酸铁铵试剂均为0.23 mL/min,酚试剂为1.00 mL/min,反应混合圈为5匝。该方法检出限为0.42 mg/kg,定量限为1.40 mg/kg,加标回收率为93.00%~103.33%,5次重复测定结果的相对标准偏差均小于2%。该方法适合用于薄片企业生产质量监管。  
Abstract:A continuous flow analysis method was established for the rapid determination of total aldehyde group content of formaldehyde and acetaldehyde in a new type of HNB(heating not combustion) cigarette sheet. A new type of HNB special sheet sample (cut up to 0.5 cm×0.5 cm) 0.500 0 g was weighed, 50 mL of 0.01 mol/L sodium hydroxide solution and 1.5 g activated carbon were added, then oscillate for 1 h, filter and collect filtrate. The aldehyde group in the filtrate reacted with the phenol reagent online to form a azine. The azine was oxidized by high ferric ion in the acid solution to form a blue-green complex with absorption at 630 nm. The change of absorbance at 630 nm was monitored by continuous flow-spectrophotometry, and the total aldehyde group content of formaldehyde and acetaldehyde in the sheet was calculated. The optimal flow rate of the instrument was 0.23 mL/min for both sample solution and ammonium ferric sulfate reagent, 1.00 mL/min for phenol reagent, and 5 turns for reaction mixing. Under the optimized experimental conditions, the limit of detection was 0.42 mg/kg, the limit of quantification was 1.40 mg/kg, the recoveries were from 93.00% to 103.33%, and the relative standard deviations of 5 determination results were all less than 2%. The method is suitable for the production quality supervision of wafer enterprises. 
关键词:连续流动分光光度法;甲醛;乙醛;加热不燃烧;新型烟草薄片 
Keywords:ontinuous flow spectrophotometer; formaldehyde; acetaldehyde; heating not combustion; new tobacco flakes 
本文引用格式:
王春琼,陈丹,秦世春,等.连续流动分析法快速测定加热不燃烧卷烟专用新型薄片中甲醛、乙醛的醛基总含量[J].化学分析计量,2021,30(11):9.
Wang Chunqiong,Chen Dan,Qing Shichun,et al. Rapid determination of total aldehyde group contents of formaldehyde and acetaldehyde in new HNB cigarette sheet by continuous flow analysis[J]. Chemical analysis and meterage,2021,30(11):9. 

全文:
相似文章:
  气相色谱法测定加热不燃烧再造烟叶中烟碱
2022年第10期
  柱前衍生高效液相色谱法测定尼莫地平注射液中的甲醛和乙醛
2022年第01期
  一种基于量子点复合薄膜甲醛气体荧光传感器的研制
2021年第09期
  室内空气中甲醛检测方法研究进展
2021年第08期
  气候箱法测定人造板甲醛释放量不确定度评定
2021年第08期
  紫外可见分光光度法测定壁纸中甲醛的不确定度评定
2021年第01期
  分光光度法测定饲料中尿素不确定度评定
2020年第06期
  分光光度法测定空气中甲醛不确定度评定
2020年第02期
  分光光度法甲醛测定仪的校准
2019年第z1期
  气相色谱-质谱法测定眼用全氟丙烷气体中甲醇、甲醛
2019年第01期
《化学分析计量》杂志社 版权所有,未经授权禁止复制或者建立镜像
地址:山东省济南市天桥区田庄东路3号 邮编:250031
电话:0531-85878132 85878224 85878278
鲁ICP备05018524号-6