火焰原子吸收光谱法测定小儿生血糖浆中硫酸亚铁
印成霞1,赵文2
1. 东营市食品药品检验中心,山东东营 257091; 2. 广饶县人民医院,山东东营 257300 
Determination of ferrous sulfate in Xiao’er Shengxue Syrup by flame atomic absorption spectrometry
Yin Chengxia1, Zhao Wen2
1. Dongying Center for Food and Drug Inspection, Dongying 257091, China; 2. The People's Hospital of Guangrao, Dongying 257300, China 
摘要:建立火焰原子吸收光谱法测定小儿生血糖浆中硫酸亚铁的分析方法。采用火焰原子吸收光谱法测定小儿生血糖浆中铁的浓度,根据铁的浓度换算成硫酸亚铁的浓度。火焰燃烧类型为空气-乙炔,测定波长为248.3 nm,测定时间为4.0 s,燃气流量为0.9 L/min,燃烧器高度为7.2 mm,氘灯作为背景校正。结果表明,小儿生血糖浆中铁元素的质量浓度在1.6~24.0 μg/mL 范围内与吸光度呈良好的线性关系,相关系数为0.999 9,方法的检出限为0.196 μg/mL,定量限为0.653 μg/mL。测定结果的相对标准偏差为0.63%(n=6),样品加标回收率为93.54%~97.65%。该方法分析速度快,专属性强,灵敏度高,可用于小儿生血糖浆中硫酸亚铁的测定。 
Abstract:A method of the determination of ferrous sulfate in Xiao'er Shengxue Syrup by flame atomic absorption spectrometry was established. The concentration of iron in Xiao'er Shengxue Syrup was determined by flame atomic absorption spectrometry and converted into the concentration of ferrous sulfate. The flame combustion type was air acetylene, the detection wavelength was 248.3 nm, the measurement time was 4.0 s, the gas flow rate was 0.9 L/min, the burner height was 7.2 mm, and the deuterium lamp was used as background correction. The results showed that the mass concentration of iron in Xiao'er Shengxue Syrup had a good linear relationship with the absorbance in the range of 1.6-24.0 μg/mL, the correlation coefficient was 0.999 9, the detection limit was 0.196 μg/mL, and the quantification limit was 0.653 μg/mL. The relative standard deviation of the determination results was 0.63%(n=6), and the recoveries were 93.54%-97.65%. The method is rapid, strong specificity and high sensitivity, which can be used for determinate of ferrous sulfate in Xiao'er Shengxue Syrup. 
关键词:火焰法原子吸收光谱法;小儿生血糖浆;硫酸亚铁 
Keywords:flame atomic absorption spectroscopy; Xiao’er Shengxue Syrup; ferrous sulfate 
本文引用格式:
印成霞,赵文. 火焰原子吸收光谱法测定小儿生血糖浆中硫酸亚铁[J]. 化学分析计量,2021,30(2):65.
Yin Chengxia,Zhao Wen. Determination of ferrous sulfate in Xiao’er Shengxue Syrup by flame atomic absorption spectrometry[J].Chemical Analysis and Meterage,2021,30(2):65. 

全文:
相似文章:
  硫酸亚铁铵滴定法测定低品位石煤钒矿中的五氧化二钒
2019年第05期
  还原分离-硫酸亚铁铵返滴定法测定碲化铜中碲
2018年第06期
  火焰原子吸收分光光度法测定维血康颗粒中总铁
2017年第04期
  恒电流库仑分析法测定硫酸亚铁铵等基准试剂的纯度
2005年第05期
《化学分析计量》杂志社 版权所有,未经授权禁止复制或者建立镜像
地址:山东省济南市天桥区田庄东路3号 邮编:250031
电话:0531-85878132 85878148 85878224 85878278 传真:0531-85947355
鲁ICP备05018524号-6