《化学分析计量》 2021年第02期
DOI:10.3969/j.issn.1008-6145.2021.02.004
紫外分光光度法测定硝酸盐氮铁离子的干扰及快速去除
董志浩,张娇
青岛农业大学资源与环境学院,青岛市农村环境工程研究中心,山东青岛 266109 
Interference and rapid elimination of ferric iron in determination of nitrate nitrogen by ultraviolet spectrophotometry
Dong Zhihao, Zhang Jiao
Qingdao Engineering Research Center for Rural Environment College of Resource and Environment, Qingdao Agricultural University, Qingdao 266109, China 
摘要:采用紫外分光光度法测定硝酸盐氮时,三价铁对测定结果有很大影响,干扰强度随着三价铁浓度的增加、硝酸盐浓度的降低而增加;三价铁对硝酸盐氮测定结果的影响随着pH 值的增加逐渐增强,当pH < 6、三价铁浓度为10 mg/L 时,相对误差为21%~61% ;pH > 7 时,干扰迅速增强,当pH 值为11 时,相对误差达530%。盐酸羟胺对三价铁有较好的掩蔽效果,当pH 值为3、三价铁与盐酸羟胺的质量浓度比为1.4∶1 时,掩蔽效果最好;当硝酸盐氮质量浓度为1~3 mg/L 且三价铁浓度低于5 mg/L 时,硝酸盐氮测定结果相对误差小于5%。 
Abstract:Ferric iron has great influence on the determination result in the determination of nitrate nitrogen by UV spectrophotometry. The interference intensity increased with the increase of ferric ion concentration and the decrease of nitrate concentration. The effect of ferric iron on the determination results of nitrate nitrogen gradually increased with the increase of pH. When the concentration of ferric iron was 10 mg/L and pH < 6, the relative error ranged from 21% to 61%, and when pH > 7, the interference increased rapidly. The relative error reached 530% at pH 11. Hydroxylamine hydrochloride had good masking effect on ferric iron. The ferric iron could be well masked when pH was 3 and the ratio for mass concentration of ferric iron to hydroxylamine hydrochloride was 1.4∶1. When the concentration of nitrate nitrogen was 1-3 mg/L and that of ferric iron was lower than 5 mg/L, the relative error of nitrate nitrogen determination result was less than 5%. 
关键词:硝酸盐氮;紫外分光光度法;三价铁;盐酸羟胺 
Keywords:nitrate nitrogen; UV spectrophotometry; ferric iron; hydroxylamine hydrochloride 
本文引用格式:
董志浩,张娇. 紫外分光光度法测定硝酸盐氮铁离子的干扰及快速去除[J]. 化学分析计量,2021,30(2):17.
Dong Zhihao,Zhang Jiao. Interference and rapid elimination of ferric iron in determination of nitrate nitrogen by ultraviolet 

全文:
相似文章:
  离子色谱法测定固体废弃物中氨氮、亚硝酸盐氮和硝酸盐氮
2020年第04期
  超声辅助浸提-紫外分光光度法测定酸枣中黄酮
2019年第06期
  气相分子吸收光谱法快速测定土壤中亚硝酸盐氮
2019年第06期
  离子色谱法快速测定土壤中的亚硝酸盐氮和硝酸盐氮
2018年第06期
  紫外分光光度法快速测定橡胶油中的芳烃
2018年第03期
  水杨酸钠紫外分光光度法测定烟草中的总氮
2017年第06期
  国标法测定地表水中阴离子表面活性剂方法优化
2017年第03期
  原子荧光光谱法测定萤石中的微量铅
2017年第01期
  紫尿酸-Fe(Ⅲ)分光光度法测定盐酸羟胺
2014年第06期
  紫外分光光谱法快速测定原料油中芳香烃的含量
2014年第03期
《化学分析计量》杂志社 版权所有,未经授权禁止复制或者建立镜像
地址:山东省济南市天桥区田庄东路3号 邮编:250031
电话:0531-85878132 85878148 85878224 85878278 传真:0531-85947355
鲁ICP备05018524号-6