离子色谱法测定环境空气PM2.5中硫酸根离子浓度不确定度评定
吴梦溪,曾晖,张颖,相倩倩,邓颖,黄文耀
湖北省疾病预防控制中心应用毒理湖北省重点实验室,武汉 430079 
Evaluation of uncertainty for the determination of sulfate ion concentration in ambient air PM2.5 by ion chromatography
吴梦溪,曾晖,张颖,相倩倩,邓颖,黄文耀
Hubei Provincial Center for Disease Control and Prevention, Hubei Provincial Key Laboratory for Applied Toxicology, Wuhan 430079, China 
摘要:根据JJF 1059.1-2012 《测量不确定评定与表示》,建立离子色谱法测定环境空气PM2.5中硫酸根离子浓度的测量不确定度评定方法。依据HJ 194-2017 《环境空气质量手工监测技术规范》进行采样、运输和保存,依据HJ 799-2016 《环境空气 颗粒物中水溶性阴离子(F -,Cl -,Br -,NO2 -,NO3 -,PO4 3-,SO3 2-,SO4 2-)的测定 离子色谱法》进行环境空气PM2.5中硫酸根离子的测定,建立测量模型,确定不确定度来源,对各个不确定度分量进行评定,并计算合成标准不确定度。环境空气PM2.5中硫酸根离子的合成标准不确定度为0.058 μg/m 3,扩展不确定度为0.12 μg/m 3,硫酸根离子的测量结果为(2.26±0.12) μg/m 3。标准曲线拟合过程中引入的相对标准不确定度和平行样重复性测定引入的相对标准不确定度较大,是提高该测定结果准确度的关键。  
Abstract:According to JJF 1059.1-2012 Evaluation and Expression of Measurement Uncertainty, the evaluation method of measurement uncertainty for the determination of sulfate ion concentration in ambient air PM2.5 by ion chromatography was established. Sampling, transportation and storage were carried out according to HJ 194-2017 technical specification for manual monitoring of ambient air quality, and HJ 799-2016 determination of water-soluble anions (F -, Cl -, Br -, NO2 -, NO3 -, PO4 3-, SO3 2-, SO4 2-) in ambient air particles by ion chromatography was used to determine sulfate ion in ambient air PM2.5. The measurement model was established to determine the source of uncertainty, and the each component of uncertainty were evaluated, and the combined standard uncertainty was calculated. The standard uncertainty of sulfate ion synthesis in ambient air PM2.5 was 0.058 μg/m3, the expanded uncertainty was 0.12 μg/m3, and the measurement result of sulfate ion was (2.26±0.12) μg/m3. The relative standard uncertainty introduced in the calibration curve fitting process and the repeatability measurement of the parallel samples is relatively large, which is the key to improve the accuracy of the determination results.  
关键词:离子色谱;PM2.5;不确定度 
Keywords:ion chromatography; PM2.5; uncertainty 
本文引用格式:
吴梦溪,曾晖,张颖,等.离子色谱法测定环境空气PM2.5中硫酸根离子浓度不确定度评定[J].化学分析计量,2020,29(6):141-145.
WU M X,ZENG H,ZHANG Y,et al. Evaluation of uncertainty for the determination of sulfate ion concentration in ambient air PM2.5 by ion chromatography[J]. Chemical analysis and meterage,2020,29(6):141-145. 

全文:
相似文章:
  Top-down控制图法评定石墨炉原子吸收光谱法测定血中铅含量的不确定度
2024年第02期
  气相色谱法测定酱油中对羟基苯甲酸甲酯的不确定度评定
2024年第02期
  Top-down法评定EDTA络合滴定法测定海洋沉积物中碳酸钙含量的不确定度
2024年第01期
  超高效液相色谱-串联质谱法检测蘑菇中6种蘑菇毒素的不确定度评定
2024年第01期
  基于WPSVBA编程的Top-Down法评定化学分析测量不确定度
2023年第11期
  电感耦合等离子体原子发射光谱法测定药用缓释材料中锡含量的不确定度评定
2023年第11期
  一种溶解氧测定仪自动检定装置的研制
2023年第11期
  二十二碳六烯酸标准样品的研制
2023年第11期
  气相色谱法测定电子烟烟液中烟碱、丙二醇和丙三醇的不确定度评定
2023年第10期
  气相色谱法测定中、长链脂肪乳注射液中大豆油和中链甘油三酸酯含量的不确定度评定
2023年第10期
《化学分析计量》杂志社 版权所有,未经授权禁止复制或者建立镜像
地址:山东省济南市天桥区田庄东路3号 邮编:250031
电话:0531-85878132 85878224 85878278
鲁ICP备05018524号-6