ICP-MS法同时测定儿童洗涤护肤产品中17种有毒有害元素
黄让明,辛希奕,林于淳,施煜,朱虹
广东省汕头市质量计量监督检测所,广东汕头 515041 
Simultaneous determination of 17 kinds of poisonous and harmful elements in children’s detergent and skin care products by ICP-MS
HUANG Rangming, XIN Xiyi, LIN Yuchun, SHI Yu, ZHU Hong
Guangdong Shantou Institute of Quality and Metrology Supervision Testing, Shantou 515041, China 
摘要:建立电感耦合等离子体质谱法同时测定儿童洗涤护肤产品中铝、锑、砷、钡、硼、镉、铬、钴、铜、铅、锰、汞、镍、硒、锶、锡和锌17种有毒有害元素的方法。样品采用微波消解法处理,通过在线内标及碰撞反应池技术校正基体效应,并优化了仪器的工作参数。测定锌的线性范围为5~1000 μg/L,砷、镉、铬、汞的线性范围为0.5~100 μg/L,其它12种元素的线性范围为1~200 μg/L,相关系数均在0.999以上,方法检出限为1.0~25.7 μg/kg。加标平均回收率为88.6%~103.2%,测定结果的相对标准偏差均小于5%(n=6)。该方法快速、简便、准确,可应用于儿童洗涤护肤产品中有毒有害元素的测定。 
Abstract:A method for simultaneous determination of 17 kinds of poisonous and harmful elements such as aluminum, antimony, arsenic, barium, boron, cadmium, chromium, cobalt, copper, lead, manganese, mercury, nickel, selenium, strontium, tin and zinc in children's detergent and skin care products by inductively coupled plasma mass spectrometry was established. The samples were pretreated with microwave digestion. The matrix effect was corrected by the online internal standard and the collision reaction pool technique, and the working parameters of the instrument were optimized. The linear range was 5-1000 μg/L for Zn, 0.5-100 μg/L for As, Cd, Cr, Hg, and 1-200 μg/L for other elements. The correlation coefficients were more than 0.999, the detection limits were 1.0-25.7 μg/kg. The average recoveries were 88.6%-103.2%, and the relative standard deviations of detection results were less than 5%(n=6). This method is fast, simple and accurate, which can be applied to the determination of poisonous and harmful elements in children's detergent and skin care products. 
关键词:电感耦合等离子体质谱法;儿童洗涤护肤产品;有毒有害元素 
Keywords:inductively coupled plasma mass spectrometry; children's detergent and skin care product; poisonous and harmful element 
本文引用格式:
黄让明,辛希奕,林于淳,等. ICP-MS法同时测定儿童洗涤护肤产品中17种有毒有害元素[J].化学分析计量,2018,27(2):27-31.
HUANG R M,XIN X Y,LIN Y C,et al. Simultaneous determination of 17 kinds of poisonous and harmful elements in children's detergent and skin care products by ICP-MS[J]. Chemical analysis and meterage,2018,27(2):27-31. 

全文:
相似文章:
  电感耦合等离子体质谱法测定苦瓜药材中16种无机元素
2019年第06期
  电感耦合等离子体质谱法同时测定药用辅料山梨醇中的铅和镍
2019年第06期
  电感耦合等离子体质谱法测定土壤中有效态镉
2019年第05期
  ICP-MS法测定土壤中12种金属元素时的样品前处理方法
2019年第04期
  ICP-MS法测定新会柑普茶元素溶出特性
2019年第04期
  ICP-MS法测定镍基单晶高温合金DD416中的镓、锡、锑、铅、铋
2019年第04期
  微波消解-电感耦合等离子体质谱法测定鲤鱼、河蚌样品中的铜、镉、铅、铬
2019年第03期
  微波消解-电感耦合等离子体质谱法测定新西兰蜂蜜中45 种元素
2019年第02期
  逆王水微波消解-电感耦合等离子体质谱法测定地球化学样品中的碘和溴
2019年第01期
  国防专用无机成分量标准物质定值技术
2018年增刊
《化学分析计量》杂志社 版权所有,未经授权禁止复制或者建立镜像
地址:山东省济南市天桥区田庄东路3号 邮编:250031
电话:0531-85878132 85878148 85878224 85878278 传真:0531-85947355
鲁ICP备05018524号-6